High frequency rack mounted long machine UPS technical advantages
1. High efficiency and energy
saving: High frequency UPS adopts high frequency switching technology, and its
switching frequency is usually tens of kHz or even higher. Compared with
traditional low frequency UPS, the size of components such as transformers and
filters of high frequency UPS is greatly reduced, thereby improving the
efficiency of power conversion, reducing energy consumption, and effectively
saving operating costs
2. Power factor correction:
High frequency UPS can better perform power factor correction, making the input
power factor close to 1, which means that it can more effectively absorb power
from the mains, reduce harmonic pollution to the power grid, improve the power
supply quality of the power grid, and also reduce the user's electricity cost
3. Fast response: The fast
switching characteristics of high frequency switching devices enable UPS to
respond more quickly to mains fluctuations, load changes, etc., and adjust the
output voltage and frequency in time to ensure the stability of the output
power supply and provide reliable power guarantee for load equipment.
Advantages of rack-mounted design
1. Space saving: The standard
19-inch rack-mounted design can be easily installed in a server cabinet or
network cabinet, and integrated with other servers, switches and other
equipment, which greatly saves the floor space of the computer room, improves
space utilization, and facilitates the planning and management of the computer
room.
2. Easy maintenance: The front
and rear panels of the rack-mounted UPS are designed with interfaces, switches,
indicator lights, etc. for easy operation and maintenance. The front panel can
usually intuitively display the UPS's operating status, battery power and other
information, so that users can understand the equipment at any time; the rear
panel provides input and output power interfaces, communication interfaces,
etc., which are convenient for wiring and connecting external devices, and also
convenient for technicians to perform maintenance and repair work.
3. Good heat dissipation
performance: In order to meet the installation requirements of environments
such as computer rooms, rack-mounted UPS are usually equipped with efficient
heat dissipation systems, such as fans, heat dissipation ducts, etc. These heat
dissipation measures can effectively reduce the heat generated by the UPS
during operation, ensure that the equipment works stably within the normal
temperature range, and extend the service life of the equipment.
High frequency rack mounted long machine UPS features and
applications
1. Long delay configuration:
Compared with standard machines, the biggest feature of long machines is that
they can flexibly configure battery packs according to different needs of
users, thereby achieving a longer backup power supply. Users can choose the
appropriate number and capacity of batteries according to the importance of the
actual load, the length of the power outage and other factors to meet the
continuous power supply needs of the equipment during the power outage and
ensure the uninterrupted operation of key equipment
2. Suitable for critical loads:
High frequency rack mounted long machine UPS is mainly used in places with
extremely high requirements for power supply, such as data centers, communication
base stations, financial computer rooms, medical equipment, etc. Once the
equipment in these places is out of power, it may cause serious consequences
such as data loss, communication interruption, and business paralysis.
Therefore, a long-term reliable backup power supply is required to ensure the
normal operation of the equipment.
3. High reliability: In order
to ensure reliability during long-term operation, High frequency rack mounted
long machine UPS usually adopts technologies such as redundant design and
intelligent battery management system. Redundant design can ensure the normal
operation of UPS when some components fail; intelligent battery management
system can monitor the status of the battery in real time, extend the battery
life, and improve the reliability of the entire system.
High frequency rack mounted long machine UPS Model
Description:
Model
ED-1KR(S)
ED-2KR(S)
ED-3KR(S)
ED-6KR(S)
ED-10KR(S)
Phase
Single-phase grounding
capacity
1000VA/800W
2000VA/1600W
3000VA/2400W
6000VA/4800W
10000VA/8000W
Input voltage
100/110/115/120/127VAC or
200/208/220/230/240VAC
208/220/230/240VAC
Frequency
scope
40Hz to 70Hz
46Hzto54Hz or 56Hzto64Hz
Mains mode
88%
89%
90%
92%
93%
Battery Mode
83%
87%
88%
90%
91%
Standard machine
Battery model
Depends on the applicant
Depends on the applicant 12V/9AH
number
2
3
4
6
8
6
8
160to20(Adjustable)
Maximum charging current
1.0A/2.0A/4.0A/6.0A
1A/2A/4A/6A(Adjustable,
6A only applies to 16 batteries)
Charging voltage
27.4VDC±1%
41.0VDC±1%
54.7VDC±1%
82.1VDC±1%
109.4VDC±1%
82.1VDC±1%
109.4VDC±1%
218.4VDC±1%(Based
on 16)
Hot Tags: High Frequency Rack Mounted Long Machine UPS, China, Manufacturer, Supplier, Factory, Fashion, Discount, Quotation, Easy-maintainable