N+X modular UPS, power module 20/30KVA/3U, single cabinet supports up to 10 power
modules in parallel up to 300KVA, single cabinets can be connected in parallel
up to 4, and the maximum power is 1200KVA. Each power module has an independent
DSP control unit. Once a power module fails, it will automatically disconnect
from the system and the system can continue to operate.
Modular UPS uses a double conversion online
structure, including rectifier, inverter, charger, control circuit, input and
output and battery connector circuit breaker. Input power factor compensation,
etc. All modules can be hot-swapped online to provide the highest level of
availability and maintainability.
A control module failure will not affect
the normal operation of the system. The control module can be replaced online
with hot-swap, and the parallel connection of the power module is also
centrally managed by the control module. It runs according to the unified
parallel parameters. A power module failure can automatically exit the parallel
system without causing harm to the entire parallel system.
The modular UPS system uses an independent
static bypass module and does not use multiple static bypass structures to
avoid overload damage caused by uneven current of multiple bypasses when
switching to bypass. The output voltage accuracy of the module parallel
connection is±1%, and the parallel circulation current is <1%.
The static bypass module only contains the
static switch of the bypass, but not the static switch of the main circuit
output. Therefore, when replacing the static bypass module, it will not cause
the system to be powered off or switched to manual maintenance bypass. Online
hot-swap replacement can be achieved in battery mode.
Features and advantages of N+X
modular UPS:
N+X modular UPS has high overall efficiency, with the highest efficiency reaching
over 96%, and the system efficiency is greater than 95% when the load is above
30%;
It supports intelligent module sleep
function, which can improve the overall efficiency under light load conditions;
Ultra-wide input voltage and frequency
range, wide input voltage range: 138-485V;
Wide input frequency range: 40-70HZ,
adapting to harsh power grid environment and extending battery life;
The number of batteries is adjustable,
supporting 30-40 batteries. When there is a battery failure, after removing the
failed battery, the remaining batteries can continue to backup power for the
system:
N+X modular UPS modular redundant spare parts design, no single point of failure;
All power modules support online hot swap,
easy to expand and maintain, the whole machine power supply, fan and important
communication signals adopt redundant design, higher reliability;
The output PF can reach 1, 11% more load
than traditional UPS;
Distributed control + centralized
scheduling, the DSP in the power module is responsible for control, the energy
control unit ECM is responsible for scheduling, functional decoupling, reducing
logic complexity;